LED Emergency Luminaire 2

Carousel Image
Carousel Image
Carousel Image
Carousel Image

Overview

The LED Emergency Luminaire 2 utilises a 50mm diameter LED unit complete with a remote emergency inverter and cell pack. Easily fed through ceiling cut-outs of 40mm and with optional graphite or white finishes, the LED Emergency Luminaire 2 provides a discreet yet functional emergency solution.

Features

Utilises the latest Luxeon Rebel LED technology
Thermally optimised die-cast body
Can be installed through ceiling cut outs of 40mm in diameter
Available in graphite or white finishes
3 hour duration
110° beam angle as standard. Optional 60° also available
Self-Test and DALI Addressable versions available

Materials and Finishes

LED HeadDie-cast Aluminium
FinishChoice of Graphite or White

Technical Details

GearRemote LED Emergency Inverter and Cell Pack
Light Source
LED

Spacing Data

Spacing Data for LEDEL2NM 110°

Level1 lux centre line0.5 lux minimum
Mounting Height2.5m4.0m2.5m4.0m
Trans to Wall3.04.13.34.7
Trans to Trans6.79.57.510.5
Axial to Trans6.79.57.510.5
Axial to Axial6.79.57.510.5
Axial to Wall3.04.13.34.7
Trans to Wall
Trans to Trans
Axial to Trans
Axial to Axial
Axial to Wall

Spacing Data for LEDEL2NM 60°

Level1 lux centre line0.5 lux minimum
Mounting Height2.5m4.0m2.5m4.0m
Trans to Wall2.32.82.93.4
Trans to Trans5.96.97.38.7
Axial to Trans5.96.97.38.7
Axial to Axial5.96.97.38.7
Axial to Wall2.32.82.93.4
Trans to Wall
Trans to Trans
Axial to Trans
Axial to Axial
Axial to Wall

Product Dimensions

LED Emergency Luminaire 2 Dimensional Diagram

R C D
DCR
LED Emergency Luminaire 2504036

Options and Variations

Order CodeDescriptionLight SourceNom. Power (W)Nom. Weight (kg)
LEDEL2NMG3hr Non-Maintained Emergency LED 110° Graphite Bezel3.0153lm LED0.32
LEDEL2NMW3hr Non-Maintained Emergency LED 110° White Bezel153lm LED3.00.32
LEDEL2NMG603hr Non-Maintained Emergency LED 60° Graphite Bezel131lm LED3.00.32
LEDEL2NMW603hr Non-Maintained Emergency LED 60° White Bezel131lm LED3.00.32

Advanced Emergency Option

EAD
Integral 3hr Non-Maintained Addressable Emergency via DALI Emergency System
ELA
Integral 3hr Non-Maintained Self Testing Emergency
Notes
Non-maintained mode; where power LED is only illuminated when the mains power fails.

Order Code Builder

Use the options below to construct and refine your required luminaire code and desired specification. Items marked * are required on all variations.

Installations Gallery

The LED Emergency Luminaire 2 has been used to great effect on the following highlighted projects.

Classification

Apollo Lighting Ltd

Unit D9 Cross Green Approach
Leeds
LS9 0SG

Tel: 0113 240 5511

Fax: 0113 240 5151

Web: www.apollolighting.co.uk

QR Code